  • -73°C to +175°C Temperature Range
  • 27 Cu Ft Workspace, 40 W x 32 H x 36.5 D (765 liters)
  • Your choice of the NEW F4T Touch Screen Controller or the Original F4 Controller
  • High/Low Limit Control and Alarm
  • Viewing Window & Interior Light
  • 4in Access Ports on Left & Right Side
  • Non-CFC Cascade Refrigeration
  • Scroll Compressors for Quiet and Efficient Operation
  • 3 Year Parts, 1 Year Labor Warranty
  • Fast Delivery From Stock
  • Made in the USA

TestEquity GSA Schedule for Environmental Chambers

Input voltage option must be specified at time of order
Opt. 0722: 230V, 3PH, 60Hz
Opt. 0724: 208V, 3PH, 60Hz
See Options & Accessories tab for export and other voltage options.

Your choice of the NEW F4T Touch Screen Controller or the Original F4 Controller

F4T Controller F4 Controller
F4T Touch Screen Controller
Modern touch screen interface
and connectivity
Original F4 Controller
Developed in 1998

NEW F4T Touch Screen Temperature Controller
The F4T is our next-generation controller. Featuring a touch-screen interface, it's exceptionally easy and intuitive to use. Includes RS-232 and Ethernet interfaces. GPIB is available as an option.

F4T Feature F4T Benefit
4.3 inch TFT Projected Capacitive (PCAP) color graphic touch screen Modern interface for quick entry and readout of parameters and functions
Direct alphanumeric parameter entry Quick and unambiguous entry of parameters for ease-of-use
Multiple levels of password security Prevent tampering of critical parameters and processes by unauthorized persons
Profile archiving and transfer via USB Flash Drive Quickly and easily transfer profiles to multiple chambers
Data Logging with transfer via USB Flash Drive or LAN Simplify your documentation process
Graphical Trend Display Eliminate circular chart recorders which have limited usefulnes
SCPI Commands Easy programming of set points and readback of chamber conditions via Ethernet
F4 Compatibility Mode for most frequently used commands Use your existing software that was written for the original F4
NEMA 4 / IP65 Rated Front panel protects the controller against damage from dust and water intrusion

More about the F4T Touch Screen Controller >>

Original F4 Temperature Controller
Up to 256 steps can be programmed into as many as 40 nameable profiles. The context sensitive information key and guided steps make profile programming fast and easy. A four-line backlit LCD displays programming, setup, operating and help information. A large LED readout indicates the actual chamber temperature with 0.1° resolution. Internal logic provides refrigeration compressor control for responsive and reliable performance. Includes two alarms and seven event outputs to control remote devices. RS-232C communications is also included. GPIB, Ethernet and analog retransmit are available as options.
More about the Original F4 Temperature Controller >>


High/Low Temperature Limit Controller and Alarm
Provides independent protection against excess temperatures. Both high and low limits can be set. The upper LED readout indicates the actual chamber temperature while the lower readout indicates the status The limit controller will shut down the chamber and trigger the audible alarm in the event of an out of limit condition. A set of uncommitted contacts are available to provide a safety power interlock for your test sample.

Viewing Window
Our unique design virtually eliminates exterior window sweating during normal temperature cycling conditions.

Two 4 inch Access Ports
Lets you attach wires and sensors to your test sample through both the left and right side of the chamber.

Adjustable Shelf
A heavy-duty stainless steel wire shelf ensures proper airflow around your test sample for uniform temperature distribution.

Chamber Condensate Drain
The chamber floor is sloped and has a drain to permit removal of condensate that can occur when cycling from low to high temperatures.

Casters
Rugged casters permit easy movement.

Built-In Refrigeration Gauges
Provides system status for easy preventive maintenance and service.

World's Best Environmental Chamber Warranty
Only TestEquity offers a 3-year warranty on parts and 1-year warranty on labor. Our nationwide service network is qualified to do the job right. And we always have replacement parts in stock for immediate shipment. Labor warranty applies to the United States and Canada only. See the complete warranty statement here.

TECHNICAL FEATURES

No-Sweat Cabinet
We use a combination of structural foam and fiberglass blanket insulation for a higher combined R-factor than just fiberglass alone. The door sealing surface is kept warm by circulating excess heat from the refrigeration system. The result is a cabinet that does not sweat due to condensation during low temperature operation.

The window is constructed of 6 panes of tempered glass separated by low-conductivity spacers to keep thermal losses to a minimum. Our unique design virtually eliminates exterior window sweating during normal temperature cycling conditions.

The stainless-steel interior liner is heliarc welded, while the refrigeration compartment behind the liner is double-insulated and carefully sealed. These design features reduce thermal losses and prevent moisture migration, ensuring years of optimum performance while keeping the cabinet rust-free.

Reliability & Safety That's Designed In
Non-CFC refrigerants are used in a cascade (two compressors) configuration. Expansion valves provide optimum performance throughout the operating range. Pressure regulators keep the operating pressures within safe limits regardless of load conditions. Liquid injection ensures cool compressor operation during high-temperature pull down for long life. Sequential starting of each compressor reduces the current demand on start-up. Each compressor is protected by high/low pressure switches. Care has been taken to use a minimum number of fittings, joints and welds to reduce the possibility of refrigerant leaks.

All electrical control components are UL approved. Each branch circuit is individually protected with class-CC fuses. A main power disconnect switch is provided on the front panel. The nichrome air-heater has a low watt-density and even heat distribution for reliable performance and fast response. A fusible link provides fail-safe protection against thermal runaways, in addition to the microprocessor-based high/low limit controller.

The side and rear panels are removable to permit complete access to the refrigeration system for ease of service and preventive maintenance.

About Copeland Glacier Compliant Scroll® Compressors
Compliant Scroll is the most reliable, most efficient and quietest compressor technology available today. Copeland's design allows the compressor to be more tolerant of liquid refrigerant and debris. Compliant Scroll compressors perform at higher efficiency levels than reciprocating compressors. They also have 50% fewer moving parts, which increases reliability and reduces sound levels. More about Scroll Compressors >>

Should I buy a TestEquity 1027S Single-Stage or 1027C Cascade Chamber?

TestEquity Single-stage refrigeration systems are capable of achieving workspace temperatures down to -35°C. This is fine for many commercial and industrial tests that require low temperatures of typically 0°C, -10°C or -25°C. A single-stage system uses one compressor to directly cool the workspace. Single-stage systems offer these benefits over similarly-sized cascade systems:

  • Faster cooling rates.
  • Higher live-load capacity.
  • Quieter operation, more energy efficient (one compressor instead of two).
  • Higher anticipated reliability and lower cost of maintenance over the life of the chamber.

TestEquity Cascade refrigeration systems are capable of achieving workspace temperatures down to -73°C. This is required for many ruggedized industrial, automotive and military tests that require low temperatures of typically -40°C, -55°C or -65°C. A cascade system uses two interdependent compressors. One compressor (low-stage) directly cools the workspace. The other compressor (high-stage) cools a heat-exchanger (cascade condenser) to remove heat from the low-stage. If you need to go below -35°C, choose the TestEquity 1027C.

Need a faster chamber? Check out TestEquity Model 3007C FastRate™ Temperature Chamber with fast temperature transition rates in excess of 10°C/minute.

Click here for TestEquity Model 3007C FastRate™ Temperature Chamber


Features Dual 3.5 HP Scroll Compressors, Window/Light
Interior Volume 27 Cu Ft
No. of Ports 2 x 4"
Temperature, Lowest -73C
Condition New
Maximum AC Current 35A/39A
Temperature, Highest +175C
Input Voltage 208/230V, 60Hz, 3 PH
Inside Dimension Width 40"
Interface RS-232, Ethernet
Inside Dimension Height 32"
Inside Dimension Depth 36.5"
LN2 Boost Cooling No
Frame Type Floor-Standing