Fluke FLUKE-773 Milliamp Process Clamp Meter

product id: 68431

Category: Data Acquisition and Meters, Multimeters

Manufacturer: Fluke

InstruHub is a leading supplier and reseller of Fluke Data Acquisition and Meters, Multimeters in Saudi Arabia, and we ship to all major cities such as Riyadh, Jeddah & Dammam


  • Best in class 0.2% accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ”breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
  • Measure 4 to 20 mA signals with in-circuit measurement
Fluke Current Clamp Meters
Environmental Specifications
Diameter of measurable conductor 0.177" or 4.5 mm max
Operating temperature -10 to 50ºC
Storage Temperature -25 to 60ºC
Operating Humidity < 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude 0 to 2000 m
IP Rating IP 40
Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight 410 g, (14.4 oz)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to
specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient 0.01% ºC
(<18ºC or > 28ºC)
Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty Three years for electronics
one year for cable and clamp assembly

Functional Specifications
mA measurement
(Measured by clamp) 771/772/773
Resolution and Range: 0 to 20.99 mA
Accuracy: 0.2%+2 counts
Resolution and Range: 21.0 mA to 100.0 mA
Accuracy: 1% + 5 counts
mA measurement
(Measured in series with test jacks) 772/773
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
mA source (Maximum mA Drive:
24 mA into 1,000 ohms)
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
mA simulate
(Maximum voltage 50 V dc)

Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts

Voltage source (2 mA maximum drive current) Resolution and Range: 0 to 10.00 V dc
Accuracy: 0.2% + 2counts
Voltatge Mesaure Resolution and Range: 0 to 30.00 V dc
Accuracy: 0.2% + 2counts

What’s the difference between the 77X models?

Fluke 771 Fluke 772 Fluke 773
Non-contact mA loop measurement Integrated mA loop troubleshooting Advanced process troubleshooting
mA measure, jaw
mA measure, in circuit
Loop power
mA source
DCV measure
DCV source
mA scaled output
mA in / out

California Safe Drinking Water and Toxic Enforcement Act of 1986 (Prop 65) Warning


Condition New

Why Buy from InstruHub:




Similar products

call
phone whatsApp mail