Bacharach HGM-MZ Multi-Zone Gas Leak Monitor

product id: 104648

Category: Leak Detectors

Manufacturer: Bacharach

InstruHub is a leading supplier and reseller of Bacharach Leak Detectors in Mongolia, and we ship to all major cities such as Mongolia


Features

  • 4 to 16 point sampling system using IR (NDIR) sensor technology, expandable to 48 points
  • Low detection limits (as low as 1 ppm)
  • Long sampling distances (up to 1,200 ft / 365 m)
  • On-board visual/audible alarms, 4 relay contacts mitigates refrigerant loss
  • Detects refrigerants (CFCs, HFCs, HCFCs, HFOs), ammonia, carbon dioxide
  • Measuring Range
    • Refrigerants: 0 to 10,000 ppm
    • Ammonia: 25 to 10,000 ppm
    • Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy:
    • Refrigerants: up to ±1 ppm ±10% of reading
    • Ammonia: up to ±10 ppm ±10% of reading
    • CO2: up to ±5 ppm ±5% of reading
  • Modbus RTU via RS 485 digital output
  • Large Graphic LCD for easy set-up andreal-time monitoring
  • Powder-coated aluminum enclosure
  • Approvals: CE, UL, CSA, EN 61010-1, EN 61326, EN 14624

What's in the Box

  • Line end filters
  • End of line water stop filter assembly
  • Manual

The Bacharach HGM-MZ Multi-zone Gas Leak Monitor offers superior performance, flexibility and functionality for low level continuous monitoring of refrigerant gases used in most commercial systems including: Chlorofluorocarbons (CFC), Hydrochlorofluorocarbons (HCFC), Hydrofluorocarbons (HFC), Ammonia (NH3) and Carbon Dioxide (CO2). These state-of-the-art fixed gas monitors lead the industry in performance, integration capabilities, initial cost and cost of ownership. Capable of detecting more than 38 refrigerant gases, the Multi-Zone system is compliant with ASHRAE standard 15-2007, is ETL Energy Saving Listed, meets California Code Regulations for Refrigerant Monitors and is EN 14624 and CE certified.

The Multi-Zone is not only a leak detection system, but enables refrigerant management of e.g. a whole supermarket. The sooner a loss of refrigerant is detected, the earlier countermeasures can be initiated, resulting in smaller recharge quantities of refrigerants. With the on-board relays and the optional remote display, the Multi-Zone fulfills the regulatory requirements as a refrigerant detection system. Using the Modbus interface or analog output, the monitor can be integrated into any BMS/BAS system.

Bacharach HGM-MZ Multi-zone monitors provide continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions. With only minor periodic maintenance, such as the occasional replacement of filters, and active diagnostics that continuously check the system for proper operation, Multi-Zone monitors help maintain your equipment efficiency, promote safety and protect the environment.

Why Buy from InstruHub:




Similar products

call
phone whatsApp mail