product id: 101377
Tripp Lite’s RBC51 premium UPS replacement battery cartridge breathes new life into UPS systems suffering from expired or weak internal batteries. Like every Tripp Lite battery cartridge, it is carefully screened and certified to meet or exceed original manufacturer specifications and ships ready for installation in your UPS system. Its reusable packaging holds expired batteries for recycling center delivery. The RBC51 is compatible with a wide variety of UPS systems, including select models from Tripp Lite, APC, Belkin, Best, Powerware, Liebert and more.
•16.6 millisecond automatic transfer between line and battery power supports UPS protection for equipment compatible with a one cycle transfer time
•750W continuous AC output in inverter mode, 1500W continuous AC output in AC mode
•DoubleBoost output supports momentary startup loads of up to 200% of the continuous rating for up to 10 seconds - OverPower output supports duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions
•3-stage selectable 11/45 Amp battery charger with adjustable settings for wet/gel/AGM battery types
•2 NEMA 5-15R GFCI protected outlets pass 120V line power or inverter output through to connected equipment
•3 position operating mode switch supports “AUTO” mode to enable automatic transfer between DC and AC modes, CHARGE ONLY to maintain a full battery charge when AC is present without auto transfer and SYSTEM OFF settings
•Set of 6 front panel LED’s display continuous status
•Set of 4 dip switches support wet/gel/AGM battery charging profiles, adjustable 135/145V high voltages and selectable 75/85/95/105V AC low voltage auto transfer during brownouts
•Set of 4 additional dip switches support 4 levels of charger limiting relative to output load size, a battery equalization program and battery charger low/high settings
•Resettable 10A charger AC input breaker and settable 12A AC output breaker and automatic 2-speed cooling fan
•Automatic overload and thermal (overheating) shutoff
•Front panel remote control connector enables remote off/on switching with included APSRM4 remote
•Load sensing control dial enables adjustable load threshold required to automatically turn the inverter on and off in DC mode as load conditions change
Includes | |