Flowline AX1X Thermo-Flo Flow Controller

product id: 103876

Category: Flow Meters

Manufacturer: Flowline

InstruHub is a leading supplier and reseller of Flowline Flow Meters in Angola, and we ship to all major cities such as Luanda


Features

  • Models AT1X and AG1X Thermo-Flo Flow Controllers
  • Set point range:
    • AT1X: 0.04 to 3 fps (0.012 to 0.91 mps)
    • AG1X: 1 to 90 fps (0.3 to 27 mps)
  • Fail-safe relay control of pumps or valves with 0 to 60 second delay
  • Pressure rating:
    • 150 psi (10 bar) @ 25°C
    • derated @ 1.667 psi (0.113 bar) per °C above 25°C
  • Sensor lengths:
    • Short: pipe or ducting from 1/2" to 1 1/2"
    • Long: pipe or ducting 2" or higher
  • Process temp: 32 to 140°F (0 to 60°C)
  • Response time: 1 to 10 seconds
  • Repeatability: ±0.5% of set point
  • LED indication: sensor, power & relay
  • Polypropylene-Ryton® or PVDF sensor for corrosive liquids & gases
  • Polypropylene enclosure rated NEMA 4X with swivel base
  • Invert switch changes relay state from NO to NC without rewiring

The Flowline AX1X Thermo-Flo Flow Controller provides reliable no or low-flow detection of relatively clean non-coating media with a 16A compact flow controller for pump or process protection. Liquid examples includes water and sulfuric acid. The optional flash alarm brings attention to low-flow alarm conditions. Available in Polypropylene-Ryton® and PVDF, the short flow sensor is used in pipe or ducting from 1/2" to 1 1/2", and the long flow sensor isused in 2"and up. The flow switch set point may be adjusted from 0.04 to 3 fps in liquids, or 1 to 90 fps in gases for low-flow control. The flow sensor is best applied in applications with relatively constant temperature.

A common problem with metering pumps in flow applications is the characteristic of the output flow. The pulsating flow makes it difficult for flow switches to get an accurate and consistent flow rate. Often flow switches will not work because they are not able to see a reliable flow output.The FlowlinePulsePoint fitting is designed to stabilize the pulsing flow for the Thermo-Flo flow switch. The cylindrical chamber creates a mini-vortex that translates to a relatively constant flow. The Thermo-Flo flow switch will be able to read the flow and provide an accurate and low-cost flow switch. The Flowline Pulse Point fitting is ideal for use in metering pump applications.

Additional features of the Flowline AX1X Thermo-Flo Flow Controller include:

  • Rugged Polypropylene-Ryton® or PVDF sensor for corrosive liquids and gases
  • Fail-safe relay control of pumps or valves with 0-60 second delay
  • Polypropylene enclosure rated NEMA 4X with swivel base for conduit alignment
  • Optional strobe brings immediate attention to flow alarm conditions
  • Invert switch changes relay state from NO to NC without rewiring
  • Solid state sensor is not damaged by over-ranging flow velocities
  • Ideal for chemical injection monitoring
  • Interfaces directly to metering pumps
  • Designed for use in corrosive media

Why Buy from InstruHub: