Keysight N9953BU/356 Noise Figure Option, 5 Types, 4 Setups, 4 Pre-Config, FieldFox Series

product id: ac75fa515930
Manufacturer:
InstruHub is a leading supplier and reseller of Keysight Component Measurement, Data Acquisition and Meters and Electronic Production Supplies in UAE, and we ship to all major cities such as Dubai, Abu-Dhabi, Sharjah

N9953BU/356 uses the Y-Factor technique to accurately verify and characterize the noise figure (NF) of devices. Option 356 has these features:

Five Measurement Types:

  • Noise Figure
  • Noise Factor
  • Gain
  • Noise Temperature
  • Y-Factor

Four Measurement Setup Types:

  • Noise Source
  • DUT
  • Integration
  • Uncertainty

Four Pre-configured DUT Measurement Types:

  • Amplifier
  • Downconverter
  • Upconverter
  • Multi-Stage Converter

Uncertainty Contribution Values can be Customized for Your Device:

  • Jitter uncertainty
  • ENR uncertainty
  • Uncertainty bars
  • Mismatch uncertainty
  • User calibration uncertainty

What are the requirements for Noise figure (NF) Option 356?

Requires spectrum analyzer mode (Option 233 on combination models), internal preamplifier (Option 235) and DC bias variable voltage source (Option 309) as well as CPU2 processor. An external noise source is also required and FieldFox supports Keysight noise source models 346A/B/C/K40/K01. Also recommended to improve accuracy is an external preamplifier Keysight models U7227A/C/F or U7228A/C/F. Requires accessory item N9910X-713 BNC to SMB cable for DC bias variable voltage source to noise source connection.

N9953BU/356 uses the Y-Factor technique to accurately verify and characterize the noise figure (NF) of devices. Option 356 has these features:

Five Measurement Types:

  • Noise Figure
  • Noise Factor
  • Gain
  • Noise Temperature
  • Y-Factor

Four Measurement Setup Types:

  • Noise Source
  • DUT
  • Integration
  • Uncertainty

Four Pre-configured DUT Measurement Types:

  • Amplifier
  • Downconverter
  • Upconverter
  • Multi-Stage Converter

Uncertainty Contribution Values can be Customized for Your Device:

  • Jitter uncertainty
  • ENR uncertainty
  • Uncertainty bars
  • Mismatch uncertainty
  • User calibration uncertainty

What are the requirements for Noise figure (NF) Option 356?

Requires spectrum analyzer mode (Option 233 on combination models), internal preamplifier (Option 235) and DC bias variable voltage source (Option 309) as well as CPU2 processor. An external noise source is also required and FieldFox supports Keysight noise source models 346A/B/C/K40/K01. Also recommended to improve accuracy is an external preamplifier Keysight models U7227A/C/F or U7228A/C/F. Requires accessory item N9910X-713 BNC to SMB cable for DC bias variable voltage source to noise source connection.

Why Buy from Instruhub:

  • Supplier of Keysight N9953BU/356 Noise Figure Option, 5 Types, 4 Setups, 4 Pre-Config, FieldFox Series in UAE
  • Best online prices for Keysight N9953BU/356 Noise Figure Option, 5 Types, 4 Setups, 4 Pre-Config, FieldFox Series
  • Wide range of Keysight products available in Dubai, Abu-Dhabi, Sharjah
  • Shipping at door with custom and duty included in price quote.

  • Instrument repair and calibration services provided.

  • InstruHub also provides DG Cargo service with as goods with Lithium Ion Batteries.

Similar products