Keysight 85056KE01 Standard Mechanical Calibration Kit, DC to 40 GHz, 2.92 mm SOLT Calibration

product id: eb4d2bf77ea1
Manufacturer:
InstruHub is a leading supplier and reseller of Keysight Component Measurement, Data Acquisition and Meters and Electronic Production Supplies in UAE, and we ship to all major cities such as Dubai, Abu-Dhabi, Sharjah


Keysight 85056KE01

Keysight 85056KE01 Standard Mechanical Calibration Kit

Perform full 2-port calibration with fixed and sliding loads using the included 2.92-mm in-series adapters

The Keysight 85056KE01 mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers. This kit supports 2.92 mm SOLT cal standards including both fixed and sliding loads. It also contains adapters to change the sex of the VNA test port from NMD 2.4 mm to 2.92 mm. Please note, these adapters are for use on VNA’s NMD 2.4 mm test port. They are not general purpose adapters. In addition, 2.92 mm in-series adapters (quantity 3) are provided. The kit also includes 5/16 torque wrench, 5/16 and 7/16 open-end wrenches for proper connection.
Included are standards definitions for PNA family VNA’s on USB stick.

Highlights

  • DC to 40 GHz frequency range
  • Calibration standards to perform full 2-port calibration with fixed and sliding loads
  • Torque wrench and open-end wrenches for properly connecting standards
  • Contains one NMD 2.4 mm (f) to 2.92 mm (f) and one NMD 2.4 mm (f) to 2.92 mm (m) test port adapter to adapt the 2.4 mm test ports of the PNA to 2.92 mm. User needs to supply appropriate 2.92 mm test port cables.
  • Contains 2.92 mm in-series adapters (3 each)
  • Standard definitions on USB stick for loading into PNA family network analyzer

The Keysight 85056A mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 2.4 mm interface. This kit also contains adapters to change the sex of the test port, connector gauges for verifying and maintaining the connector interface, and a torque wrench for proper connection.

Highlights

  • DC to 50 GHz frequency range
  • Calibration standards to perform full two-port calibration
  • Torque wrenches for properly connecting standards
  • Adapters to change the sex of the test port
  • Commercial calibration certificate
  • Includes connector gauges

Kit Contents

The 85056A calibration kit includes the following items:

  • offset opens and shorts
  • broadband and sliding load terminations
  • 2.4 mm adapters
  • 2.4 mm gage sets
  • 5/16 in, 90 N-cm (8 in-lb) torque wrench
  • 7 mm open-end wrench
  • User’s and Service Guide
  • Calibration kit storage case

Why Buy from Instruhub:

  • Supplier of Keysight 85056KE01 Standard Mechanical Calibration Kit, DC to 40 GHz, 2.92 mm SOLT Calibration in UAE
  • Best online prices for Keysight 85056KE01 Standard Mechanical Calibration Kit, DC to 40 GHz, 2.92 mm SOLT Calibration
  • Wide range of Keysight products available in Dubai, Abu-Dhabi, Sharjah
  • Shipping at door with custom and duty included in price quote.

  • Instrument repair and calibration services provided.

  • InstruHub also provides DG Cargo service with as goods with Lithium Ion Batteries.

Similar products